The Vilnius Gediminas Technical University laboratory program examined how Aires resonator-converter prototypes interact with electromagnetic fields. Phase II tested individual devices and groups; Phase III investigated how two- and three-dimensional arrangements changed the measured response. These experiments give the physics program a concrete basis: geometry, placement and interference affect the field recorded by a receiver.
Institution: VGTU, Laboratory of Photovoltaic Technology. Researchers: Artūras Jukna and Dainius Jasaitis. Reports: Phase II, 2017; Phase III, 2018.
Read the original Phase II report · Read the original Phase III report
Phase II: measure the response under defined conditions
The laboratory used a Signal Hound spectrum analyzer and sources centered at 0.9 and 2.5 GHz. The report lists source powers of 0.5, 2, 400 and 800 W. Its 0–8 GHz instrument range describes the measurement system; it is not a record of testing every frequency across that range.
In the 800 W, 2.5 GHz transmission experiment, the two resonator groups reduced the measured electric-field amplitude by averages of 25% and 22%. The report plots how the response changes with source and receiver distance. These are physical field measurements from the tested configurations.
What the 2 W threshold refers to
The Phase II analysis on printed page 12 discusses an approximately 2 W value in its 0.9 GHz excitation analysis, then separately estimates about 490 mW incident on the tested resonator surface using its geometry calculation. The conclusion rounds the latter to about 0.5 W. Keeping these quantities separate explains the experiment more accurately than a universal “2 W required” label.
The authors interpret the above-threshold response in terms of excitation of the prototype’s fractal antenna structure. These values describe that laboratory model and excitation mechanism; they are not operating instructions for today’s consumer devices.
Phase III: arrangement matters, and more is not automatically better
The Phase III introduction summarizes an earlier reflection-mode result: an average 20% field-amplitude reduction across the stated 0.9–2.5 GHz conditions, with the strongest damping at a resonator-to-receiver distance of no more than three wavelengths.
The new Phase III work examines grouped configurations at 2.4 GHz. Its conclusion states that the tested planar groups did not provide substantially greater cancellation than a single resonator. Mutual interference could increase or decrease the measured field. The authors identified a single resonator close to the receiver in reflection mode as the most effective arrangement in that comparison, and called for group modeling that accounts for contributions from both individual elements and the whole arrangement.
The research thread: model, measure, test biology
For Aires, this is valuable engineering evidence: the electromagnetic environment has spatial structure, and a device’s geometry and location matter. The program develops beyond a single meter reading to characterize how fields interact with a resonator.
The next connections are specific:
- Phase I: the earlier laboratory stage.
- C16S, C28S and C32S modeling: follow the different resonator geometries and their original reports.
- PACE’s C32S expert peer review: the assessment of the 2.4 GHz model.
- Published Sysoev–Budko EEG research: the biological response tested with Lifetune ONE in a later human protocol.
Outside Aires, controlled human research comparing pulsed and unpulsed RF illustrates why exposure characteristics matter to biological investigation. The laboratory physics and human studies answer complementary questions: how the field behaves, and how biology responds.
Continue through the physics and engineering hub, the human physiological research and the complete archive.
Updated November 4, 2026 · Aires editorial team. Original research remains credited to its authors.