What does a radiofrequency meter pick up when an Aires prototype sits beside a transmitter? In Vilnius, researchers compared the electric field at the same receiver position with and without a prototype, then repeated the comparison farther from the source. They reported an average 27% decrease in electric-field strength in the 0.9–2.5 GHz measurements with the prototype directly in front of the transmitter. See Figure 5 in the 2016 Phase I laboratory report.
Why the distance mattered
Figure 5 gives the difference between two readings at each position. The difference became smaller as the receiver moved away. For the 800 W source it disappeared beyond 1.2 metres in this setup. Reporting the source power, placement and receiver distance lets another laboratory repeat that comparison.
The team also placed a prototype between transmitter and receiver, then changed the geometry to measure a reflected signal. In the transmission arrangement its response resembled a conducting plate. In the reflection arrangement the researchers reported the strongest damping close to the receiver. Compare the arrangements in Figures 6 and 7.
Who ran the experiment?
UAB AIRESLITA commissioned the work. The Laboratory of Photovoltaic Technology at Vilnius Gediminas Technical University in Lithuania ran the tests. The report names Artūras Jukna and Dainius Jasaitis on its cover. See the commissioning organization and laboratory on the original report.
How the next tests built on it
Phase I moved an individual prototype and the receiver. The next question was whether the field would change differently with four resonators together.